Reverse Blade PC Fans

Engineered for Superior Airflow Management. LINKWELL’s specialized Reverse Blade PC Fans are designed to solve specific thermal challenges in high-density electronic enclosures and specialized cooling loops. Our expertise as a leading cabinet component manufacturer ensures reliability and performance.

Global Partnership

Size range

80mm to 140mm, with custom options available

 

Voltage

5V, 12V, 24V, and 48V supported

Operating temperature range

-10℃ to 120℃ with high-heat options

Speed

1000 to 30,000 RPM adjustable

Service life

Up to 50,000 hours continuous operation

Our Reverse Blade PC Fans Series

We provide customized Reverse Blade PC Fans solutions with flexible sizes, fast delivery, and OEM/ODM support. Contact us now for a free quote!

FU series cooling fan

FU Series

Offered in multiple sizes with pre-set embedded nuts for quick installation; an optional air duct boosts airflow efficiency.

LK32 series Cabinet fan

LK32 Series

User-friendly buckle design enables rapid maintenance access; an optional power light clearly indicates operating status.

LK66 series Cabinet cooling fan

LK66 Series

Linear grill pattern optimizes airflow distribution, delivering stronger cabinet ventilation performance.

FF series Cabinet fan

FF Series

Constructed from UV-stable PC alloy for long-term durability; optional corrugated filter mat ensures advanced dust resistance.

FK55 series Cabinet fan

FK55 Series

Slim-profile cover perfectly fits tight installations; modern curved-line grill adds an elegant touch to cabinet design.

What Are Reverse Blade PC Fans?

Unlike standard fans that blow air forward, a Reverse Blade (or Reverse Flow) PC Fan has its blade geometry and motor orientation engineered to pull air in the opposite direction. This creates an exhaust or reverse airflow pattern, which is critical for creating specific pressure zones and controlled thermal paths within a system.

Why Choose LINKWELL Reverse Blade Fans?

Feature Standard PC Fan LINKWELL Reverse Blade Fan
Primary Airflow Blows air forward (intake) Pulls air in reverse (exhaust / pull-through)
Typical Role General intake cooling Targeted exhaust, hotspot cooling, pressure control
Blade Design Standard aerodynamic pitch Optimized reverse-angle pitch for efficient reverse flow
Ideal Application Cabinet front or side intake Cabinet rear or top exhaust, behind heat sinks, paired cooling
System Impact Increases internal pressure Helps balance or reduce internal pressure

Technical Specifications & Features

Designed for demanding industrial and telecom environments, built to last.

CFM Airflow Range
40- 40
VDC Standard
0
Ingress Protection (Optional)
IP 0
dBA Noise Level
20- 0
Operating Temperature
-20 to 0 +

Core Features

Customization Options (OEM/ODM)

Key Applications & Industries

Where Our Reverse Blade Fans Make a Critical Difference

Telecom & Network Cabinets

Create precise exhaust paths in 5G enclosures and router racks to manage heat from high-power ASICs and PSUs, preventing recirculation.

Industrial Control Panels

Pair with intake filters. Use reverse fans as exhaust to maintain slight negative pressure, keeping dust out of sensitive PLCs and drives.

Power Conversion & UPS Systems

Directly extract hot air from heatsinks on IGBT modules and transformers, significantly improving component lifespan.

Gaming & High-Performance Computing

Custom reverse-flow fans for unique PC case designs or specialized cooling shrouds for water cooling radiators.

Medical & Laboratory Equipment

Provide controlled, directional airflow in enclosed instrumentation where specific thermal gradients are required.

Renewable Energy Inverters

Essential for thermal management in solar and wind power inverters installed in dusty outdoor environments.

Built with 20+ Years of Manufacturing Excellence

Your trust is built on our process. Every LINKWELL Reverse Blade Fan benefits from our vertical integration and rigorous standards.

In-House Design & Simulation

Our engineers use CFD analysis to optimize blade design for your specific reverse-flow requirements before prototyping.

Automated Production

State-of-the-art SMT lines and automated assembly ensure consistency and precision in every unit.

Automated Production

Each fan undergoes performance, noise, vibration, and life cycle testing. We provide full test reports upon request.

Global Certifications

Each fan undergoes performance, noise, vibration, and life cycle testing. We provide full test reports upon request.

Your Partner, Not Just a Supplier

electrical cabinet air conditioner factory
reverse blade pc fans manufacture
electrical cabinet air conditioner factory (3)
electrical cabinet air conditioner factory (4)
electrical cabinet air conditioner factory (2)
electrical cabinet air conditioner factory (5)

FAQs

How do I know if I need a reverse blade fan versus a standard fan?

If your design requires creating a specific exhaust point, balancing pressure between intake and exhaust, or pulling air through a restricted path (like a heatsink), a reverse blade fan is the solution. Our engineers can help you analyze your airflow needs.

Custom color matching (via Pantone codes), custom wire lengths, and specific connectors (e.g., 4-pin PWM, 3-pin, 2-pin) are standard ODM services we provide.

For standard reverse models, MOQ can be as low as 100 pcs. For fully customized designs, we discuss MOQ based on tooling and design complexity, offering flexible terms for serious partners.

Yes. We provide downloadable 3D CAD models for all our standard fan sizes to assist your enclosure design process.

We follow a strict ISO 9001-based quality management system. Every production batch undergoes sample testing for performance, noise, and hi-pot. We welcome third-party inspection.

 For standard items: 15-20 days. For customized ODM projects: 25-35 days after design confirmation. We prioritize rapid prototyping to keep your project on schedule.

Contact & Inquiry

Contact us today for detailed product information, quotes, or expert technical support. Simply complete the form with your name, email, company, country, and inquiry, and our team will get back to you quickly. You can also connect with us directly via WhatsApp, email, or phone for fast and reliable assistance.

Ask for Samples Now